1955 University Lane
Lisle, IL 60532 USA
T: 630.963.0320
F: 630.963.1928
Tungsten
Typical shielding densities approaching twice that of high density Lead Blankets of similar thickness. Highly flexible and can be molded/formed into any shape. Often competitively priced to lead alternatives. NPO will engineer and fabricate specialized profiles, slabs and ribbon, including lockable "High Rad" applications. Tested to 550°F/288°C for continuous use.
Pressurized Heater Shielding "T-Flex" Application Example
- Maximized the Shielding Impact, particularly in tight spaces
- Offering ease of installing and securing
- Integral securing straps included (lockable systems available).
- Greatly increased shielding effectiveness by custom profiling the shield relative to the "hot spot" or radiation source.
T-Flex Tungsten Shielding System
- Provides approx. 75% Attenuation as compared to solid lead
- Attenuation of 175% compared to a high density lead blanket
- Priced competitively to lead for many applications
- Available as a blanket, ribbon wrap or molded shapes; flexible or rigid
- Cut materials to fit without needing to seal edges - no residue
- Included fasteners, grommets, locking devices, etc., as required
- Improved fit-up --- molded applications typically will yield much higher reduction factors - less weight with same impact
- Tested to 550°F/288°C
Click on the photos to enlarge
Tungsten Shielding Application Example: Provide Shielding for small bore pipe using NPO's "T-Flex" Tungsten Shielding System
- Shielding of 3/4" Schedule 160 Small Bore Piping.
- Pipe O.D. of 1.05" with 9/16" of tungsten shielding yeliding a shielding O.D. of approximately 2-1/4" for a maxiumum weight of 10 lbs. per linear foot of piping
- The elbows will be formed by cutting shielding material at a 45 degree angle and butting the sections together at the elbow. Add supplemental shielding at elbows, "T"s, etc. as shielding impact will result in a Gamma transmission of 40% or better.
- Suggested lengths of 18". Lengths can be cut-to-fit as needed during installation.
NPO Part No. T62PIPSHD.75X18 Tungsten Shielding for shielding 1" O.D. (approx.) piping. Approximate weight per foot is 10 lbs. The shielding O.D. is 2-1/4" or approximately 9/16" effective shielding thickness. Provided in 18" lengths approx. 15 lbs Each.
Pricing available upon request.
NPO Part No. T62PIPKit Kit including (1) 96" roll of 1/8" x 2: Tungsten Ribbon Shielding for adding shielding as needed at elbows, etc. and (20) Velcro Straps.